INSTALLATION INSTRUCTIONS

REMOVE GRINDER FROM WOOD PALLET
To remove the grinder from the wood pallet, unbolt the brackets that hold the frame to the wood pallet. Use
a forklift to lift the machine from the pallet. THE UNIT WEIGHS 1450 LBS. [658 KG]. USE POWER EQUIPMENT
TO LIFT THE UNIT. See FIG. 3 on Page 13.
POSITION THE BASE
This machine must be positioned in an area that allows for sufficient access to all sides of the machine for
operation and service. We suggest an operating area of about 125" [318cm] x 97" [ 247cm]D x 90"H [229
cm] when loading from the front of machine or 125" [318cm] x 165" [419cm]D x 90"H [229 cm] when loading
from the back of the machine. Position the base to allow sufficient operating room in both front and behind
the machine. See Figure 2.
The base should be placed on a relatively level concrete floor, with ample ceiling height to allow for the
installation of the unit. Do not place the unit across two concrete slab seams or across a large crack.
PLACING THE GRINDER ON FLOORING THAT IS NOT LEVEL OR BROKEN WILL AFFECT GRINDING
QUALITY.
MACHINE MUST BE POSITIONED TO ALLOW EASY ACCESS TO THE MAIN POWER CORD PLUG FOR USE
AS THE MAIN DISCONNECT. SEE POWER INSTALLATION SECTION FOR ADDITIONAL INFORMATION.
ELECTRICAL REQUIREMENTS:
• ALWAYS USE A PROPERLY GROUNDED OUTLET!
• It is recommended that this reel mower grinder
has its own permanent power connection from
the power distribution panel, with no other
major power draw equipment on the same line.
• The grinder is equipped with a high-low voltage
relay (LVR) which is factory preset at 100-140
VAC. If the power supply line does not deliver
100-140 VAC power under load, the relay will open and trip out the starter. If this occurs, your power
supply line is inadequate and must be corrected before proceeding further with the grinder.
165" [419 CM]
WORKSTATION
97"
[245CM]
36"
[91CM]
125
[318CM]
AREA REQUIRED IF USING
THE OPTIONAL WORKSTATION
OPERATOR &
LOAD AREA
FOR 20 AMP-RATED LARGE MACHINE
Distance from Electrical Panel to
the Electrical Outlet Receptacle
English (feet)
Metric (meters) English (Gauge)
0-40
0-12
40-60
12-18
60-100
18-30
100-160
30-48
81
[206 CM]
12
ORIGINAL INSTRUCTIONS
Size of Wire Required
Metric (mm)
12
4.0
10
6.0
8
10.0
6
16.0
70
[178 CM]
FIG. 2