The E-Wand has an internal light sensor providing the capability to
28. Light Sensor Automation
automatically close your slats at night to provide full privacy in the room, and
open your slats in the morning to allow in natural light.
The LIGHT SENSOR SWITCH allows the user to control the light sensor and
has three positions.
Top:
Sensor is turned off.
Middle: Sensor will open the slats around sunrise and close
the slats around sunset.
Bottom: Sensor will only close the blind around sunset.
The E-Wand contains an internal temperature sensor providing the capability
29. Temperature Sensor Automation
to automatically close your slats when the temperature near the window is
around 82 F and open your slats when the temperature is around 69 F. This
function is designed to help with energy savings and provide comfort in the
room.
The TEMPERATURE SENSOR SWITCH allows the user to control the
temperature sensor and has three positions.
Top:
Sensor is turned off.
Middle: Sensor will open the slats around 69 F and
close the slats around 82 F.
Bottom: Sensor will only close the slats around 82 F.
48
30. LED Modes on CPC Bridge
Solid Blue
Bluetooth Enabled
Solid Green
Connected to Server
Solid Red
No Internet
31. E-Wand Programming Beeps
During programming, be conscious that there are several series of beeps
that correspond with the different programming stages. Be careful to not
sum up the number of beeps you have heard, for example, a SINGLE BEEP
(1) and then a DOUBLE BEEP (2) is not a TRIPLE BEEP (3).
Single Beep (1)
Pairing Mode for the Remote and Grouping
Double Beep (2)
Programming the Slat Positions Mode
Triple Beep (3)
Setting the Favorite Position
Quadruple Beep (4)
Setting the Preferred Closed Position
Quintuple Beep (5)
Master Reset
Sextuple Beep (6)
Realign the E-Wand
Flashing Blue
Join Mode
Flashing Green
Command Received
Flashing Red
Not Registered/Error
49