2. Remove the ProStop-E valve from the original Hypro nozzle body by removing the U-clip that attaches it to the
threaded nut. Pull on the valve to separate it from the nut, and spin the nut to remove it from the nozzle body.
NOTE:
Leave the ProStop-E connected to the existing cabling.
3. Remove the Hypro Nozzle body from the boom tubing.
4. Thread the ProStop-E adapter (P/N 063-0173-964) onto the threaded port of the Wilger nozzle body furthest
from the boom tube clamp.
FIGURE 4. ProStop-E Adapter Installation Location
5. Attach the Wilger nozzle body to the boom.
6. Install the Hawkeye® 2 NCV to the Wilger nozzle body port closest to the wet boom tube.
7. Using the U-clip, install the ProStop-E to the previously installed adapter.
IMPORTANT:
Ensure the flat surface on the U-clip is towards the ProStop-E body (tabs down). Failure to do so will result
in leaks and potential damage to components.
SPECIAL INSTALLATION INSTRUCTIONS
1. For the nozzle bodies on the center rack and the inner three locations of each primary boom segment, use the
modified nozzle body assembly shown below. The assembly requires the Wilger nozzle body 2-way inlet (P/N
333-0002-332), the Wilger adapter plug (P/N 333-0002-319), and Wilger end body (P/N 333-0002-325).
FIGURE 5. Completed Wilger Assembly