Skyjack SJKB-40-D Operating Maintenance Instructions & Part List page 77

Hide thumbs Also See for SJKB-40-D:
Table of Contents

Advertisement

TROUBLE
CHOKE INOPERATIVE
FROM PLATFORM
CONTROLS
(Kubota gas engines)
CHOKE INOPERATIVE
FROM BASE CONTROLS
(Kubota gas engines)
EMERGENCY PUMP IN-
OPERATIVE FROM PLAT-
FORM AND BASE CON-
TROLS
SECTION 4, Page 26
TROUBLESHOOTING (Cont.)
PROBABLE CAUSE
ELECTRICAL SYSTEM (Cont.)
1.
Loose or broken wire #60A from
platform terminal block TB2 to
choke switch S8.
2.
Defective choke switch S8.
3.
Loose or broken wire #74 from
choke switch S8 to platform
terminal block TB2.
4.
Loose or broken wire #74 from
platform terminal block TB2 to
base terminal block TB3.
1.
Loose or broken wire # 60A from
base terminal block TB3 to choke
switch S9.
2.
Defective choke switch S9.
3.
Loose or broken wire #74 from
choke switch S9 to base terminal
block TB3.
1.
Loose or broken wire #09 from base
terminal block to relay 01CR.
2.
Loose or broken wire #02 from relay
01CR to base terminal block TB3.
3.
Defective relay 01CR.
4.
Loose or broken wire #01A from
relay 01CR to relay 01CR to relay
21CR2.
5.
Loose or broken wire #21 from base
terminal block TB3 to relay 21CR2.
6.
Loose or broken wire #02 from relay
21CR2 to base terminal block TB3.
7.
Defective relay 21CR2.
8.
Loose or broken wire #108 from
relay 21CR2 to emergency pump
contactor 10BCR.
9.
Loose or broken wire #02 from
emergency pump contactor 108CR
to base terminal block TB3.
10.
Defective emergency pump motor
contactor 108CR.
11.
Loose or broken battery cable from
battery 03 to emergency pump
contactor 108CR.
JUN. 1999
REMEDY
1.
Check Continuity. Replace if
defective.
2.
Check Switch.
defective.
3.
Check Continuity. Replace if
defective.
4.
Check Continuity. Replace if
defective.
1.
Check Continuity. Replace if
defective.
2.
Check Switch.
defective.
3.
Check Continuity. Replace if
defective.
1.
Check Continuity. Replace if
defective.
2.
Check Continuity. Replace if
defective.
3.
Check Relay.
defective.
4.
Check Continuity. Replace if
defective.
5.
Check Continuity. Replace if
defective.
6.
Check Continuity. Replace if
defective.
7.
Check Relay.
defective.
8.
Check Continuity. Replace if
defective.
9.
Check Continuity. Replace if
defective.
10.
Check Contactor. Replace if
defective.
11.
Check Continuity. Replace if
defective.
SJKB-40-D, SJKB-40-D/F
Replace if
Replace if
Replace if
Replace if

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sjkb-40-fSjkb-40-rtSjkb-40-xrt