You can stop the measurement at any time by pressing the
ON/OFF button (e.g. if you feel uneasy or an unpleasant pres-
sure sensation).
5. Appearance of the Heart Arrhythmia Indicator for
early Detection
This symbol AM indicates that certain pulse irregularities were detected
during the measurement. In this case, the result may deviate from your
normal blood pressure – repeat the measurement. In most cases, this is
no cause for concern. However, if the symbol appears on a regular basis
(e.g. several times a week with measurements taken daily) we advise you
to tell your doctor. Please show your doctor the following explanation:
Information for the doctor on frequent appearance of the
Arrhythmia indicator
This device is an oscillometric blood pressure monitor that also
analyses pulse frequency during measurement. The device is clin-
ically tested.
The arrhythmia symbol is displayed after the measurement, if pulse
irregularities occur during measurement. If the symbol appears
more frequently (e.g. several times per week on measurements
performed daily) we recommend the patient to seek medical
advice.
This device does not replace a cardiac examination, but serves to
detect pulse irregularities at an early stage.
6

6. Data Memory

At the end of each measurement, this device automatically stores the
result, including date and time.

Viewing the stored values

Press the M-button 5 briefly, when the device is switched off. The
display first shows «M» AL and then a value, e.g. «M 17». This means
that there are 17 values in the memory. The device then switches to the
last stored result.
Pressing the M-button again displays the previous value. Pressing the
M-button repeatedly enables you to move from one stored value to
another.

Memory full

When the memory has stored 200 results, the memory is full.
From this point onwards, a new measured value is stored by
overwriting the oldest value.

Clearing all values

If you are sure that you want to permanently remove all stored
values, hold down the M-button (the device must have been switched
off beforehand) until «CL» appears and then release the button. To
permanently clear the memory, press the M-button while «CL» is
flashing. Individual values cannot be cleared.