Displaying the operational status of power
supplies
Use the
display power
<Sysname> display power
Power 0
Power 1
Table5-4 Output description
Field
Power
Status
Displaying the temperature information of the
firewall
Use the
display environment
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor
Temperature LowerLimit Warning-UpperLimit
pperLimit
inflow 1
NOTE:
Only the F100-A-G3, F100-E-G3, F1000-C-G3, F1000-S-G3, F1000-A-G3, and F1000-E-G3
firewalls support the
Table5-5 Output description
Field
Sensor
Temperature
LowerLimit
Warning-UpperLimit
Alarm-UpperLimit
Shutdown-Upperlimit
command to display the operational status of power supplies.
Status: Normal
Status: Absent
Description
Number of the power supply.
Power supply state:
•
•
•
command to display the temperature information of the firewall.
26
-5
display environment
Description
Temperature sensor:
•
inflow—Air inlet vent temperature sensor.
•
outflow—Air outlet vent temperature sensor.
•
hotspot—Hotspot temperature sensor.
Current temperature.
Low temperature alarm threshold.
Warning-level high temperature alarm threshold.
Alarm-level high temperature alarm threshold.
Shutdown-level high temperature alarm threshold. The firewall automatically
Normal—The power supply is operating correctly.
Absent—The power supply is not in position.
Abnormal—The power supply has failed.
48
command.
5-34
Alarm-UpperLimit Shutdown-U
56
NA