Shut down the server (if shutdown is allowed), switch the positions of the PSUs
and cross-check whether the PSU is faulty.
5.
If the instructions above do not resolve the problem, please call Inspur
Customer Service Hotline (1-844-860-0011/1-760-769-1847) or email to
serversupport@inspur.com.
7.1.6

Abnormal Drive Status LED

Symptoms:
The drive activity status LED is off or the drive fault LED illuminates red when the
server is under normal operation.
Solutions:
1.
Check if the drives are installed properly;
2.
Check whether the drivers are removed and inserted or if there are other
manual operations. If yes, restore the array through RAID configuration to
ensure the drives are configured properly;
3.
If no, run command under the OS to see if all the drives are identified. If the
server is configured with an RAID card, you can also choose to log into the RAID
management interface to check whether there is a drive failure;
4.
If there is a drive failure or the instructions above do not resolve the problem,
please call Inspur Customer Service Hotline (1-844-860-0011/1-760-769-1847)
or email to serversupport@inspur.com.
Hot-swap storage drive allows users to remove or replace the drive without
shutting down or powering off the system, which improves the system
disaster recovery capability, scalability and flexibility. It only means the
hot-swap drive can be plugged in and out online without damage.
Depending on the RAID level, hot-plugging a storage drive in the RAID may
cause RAID degradation or failure. When installing a new drive, different
RAID cards have different policies. You may need to log into the RAID
management interface for recovery.
Remove the drive until the drive motor stops completely in order to prevent
damage to the motor.