H3C S12500 Installation Manual page 68

Routing switch
Hide thumbs Also See for S12500:
Table of Contents

Advertisement

Power management function status
Power supply type, rated input voltage, and rated output power
Number of redundant power modules
Available, redundant, used, and remained power
Operating status of power modules
Power supply status of LPUs
# Display detailed information about the power supply system.
<Sysname> display power-supply verbose
Power info on chassis 0:
System power-supply policy: enable
System power-module redundant(configured): 1
System power usable: 4000 Watts
System power redundant(actual): 0 Watts
System power allocated: 3620 Watts
System power available: 380 Watts
System power used(current): 1070.00 Watts
System power monitoring unit 1:
Software version: 200
Type
In/Out
----------
------
PSE9000-A
AC/DC
DC output voltage information:
Tray Value(V)
Upper-Threshold(V)
---- --------
------------------
1
50.00
52.00
DC output current information:
Total current(A): 21.40
Branch
Value(A)
------
--------
1/1
11.80
1/2
9.60
1/3
N/A
1/4
N/A
1/5
N/A
1/6
N/A
1/7
N/A
1/8
N/A
PSU Status:
ID
Status
Input-Err
--- ------- ----------- ---------- ---------------- ------- ------ -------------
1/1
Normal
1/2
Normal
Rated-Vol(V)
Existing
------------
--------
220(default)
2
Lower-Threshold(V)
------------------
48.00
Output-Err High-Temperature Fan-Err Closed Current-Limit
60
Usable
Redundant(actual)
------
-----------------
2
0
Status
-------
Normal

Advertisement