A.2 Problem solving
Problem
The device is not operational
The monitor remains dark
The mouse pointer does not
appear on the screen
Wrong time and/or date on
the PC
Although the BIOS setting is
OK, the time and data are still
wrong.
USB device not responding.
"chkdsk" is not functioning
190
Possible cause
No power supply
Device is being operated outside
the specified ambient conditions
The brightness button has been
set to dark
Power cord is not connected
The mouse driver is not loaded
Mouse not connected.
The backup battery is dead.
The USB ports are disabled in
BIOS.
The operating system does not
support the USB ports.
EWF (Enhanced Write Filter) has
been activated. The "chkdsk"
command is not supported if the
EWF has been activated.
Possible remedy
Check the power supply, the power cord and the
power plug.
Check if the On/Off switch is in the correct position.
Check the ambient conditions.
After transport in cold weather, wait approximately
12 hours before switching on the device.
Increase brightness using the brightness button. For
detailed information, refer to the monitor operating
instructions.
Check whether the power cord has been properly
connected to the monitor and to the system unit or
to the grounded shockproof outlet.
If the monitor screen still remains dark after you
have performed these checks and measures, con-
tact your technical support team.
Check whether the mouse driver is properly installed
and available when you start the user program. De-
tailed information about the mouse driver is available
in the corresponding documentation.
Check whether the mouse cord is properly con-
nected to the system unit.
If you use an adapter or expansion for the mouse
cable, also check these connectors.
If the mouse pointer still does not appear on the
screen after you have performed these checks and
actions, contact your technical support team.
1. Press <F2> during the booting process to open the
BIOS Setup.
2. Set the time and date in the setup menu.
Replace the backup battery.
Use a different USB port or enable the port.
Turn on USB Legacy Support for mouse and key-
board.
For other devices, you need the USB device driv-
ers for the required operating system.
Deactivate the EWF or use an alternative method to
"chkdsk".