Test voltages
Insulation resistance is demonstrated in the type test with the following test voltages in
accordance with IEC 61131-2:
Circuits with a nominal voltage of U
circuits or ground
< 50 V
Protection class
Protection Class I in accordance with IEC 60536, i.e. PE/ground connection required.
Protection against foreign objects and water
The following degree of protection applies to the PRO device:
Device side
all sides
8.4.2.4

Rated voltages

The table below shows the rated voltage and the corresponding tolerance range.
Rated voltage
+24 VDC
156
to other
Test voltage
e
500 V DC
Degree of protection
IP65 according to IEC 60529
Enclosure Type 4X / 12 (indoor use only) ac-
cording to UL50
Tolerance range
19.2 to 28.8 V (+/–20%)