Tools And Supplies Needed; Safety Information - EMC2 Data Domain DD2500 Installation And Setup Manual

Table of Contents

Advertisement

Tools and supplies needed

Safety information

For information about:
How to install and use the DD Boost software
and plug-in
How to replace Data Domain hardware
components
How to use third-party applications
For a list of recommended tools and supplies for field work, see the document titled FE
Toolkit Inventory and Common Procedures for FRU Tasks at https://support.emc.com.
CAUTION
If the system is used in a manner not specified by the manufacturer, the protection
l
provided by the equipment may be impaired.
The RJ-45 sockets on the motherboard, PCI cards, or I/O modules are for Ethernet
l
connection only and must not be connected to a telecommunications network.
Review this list of important safety recommendations.
All plug-in modules and blank plates are part of the fire enclosure and must be
l
removed only when a replacement can be added immediately. The system must not
be run without all parts in place.
A controller must be operated only from a power supply input voltage range of 100–
l
240 VAC, 50–60 Hz.
Each component is intended to operate with all working power supplies installed.
l
Provide a suitable power source with electrical overload protection.
l
A safe electrical earth connection must be provided to each power cord. Check the
l
grounding of the power sources before applying power.
The plug on each power supply cord is used as the main disconnect device. Ensure
l
that the socket outlets are located near the equipment and are easily accessible.
Permanently unplug the unit if you think it is damaged in any way and before moving
l
it. If the unit is powered by multiple sources, disconnect all supplied power for
complete isolation.
The power connections must always be disconnected prior to removal or replacement
l
of a power supply module from any of the components in the system.
A faulty or failed fan module should be replaced as soon as possible. A faulty or
l
failed power supply module must be replaced within 24 hours.
EMC Data Domain systems are heavy. Use two people or a mechanical lift to move
l
any system.
To comply with applicable safety, emission, and thermal requirements, covers must
l
not be removed and all bays must be fitted with plug-in modules.
EMC Data Domain DD2500 System Installation and Setup Guide
Go to
https://support.emc.com/
EMC Data Domain Boost for OpenStorage
Administration Guide for your software release
Specific part installation guides
Integration documentation and compatibility
matrices
Tools and supplies needed
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Data Domain DD2500 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF