Maintenance; Cleaning; Replacing Fuses; D Replacing Dc Power Cable Fuses - Icom ID-RP2010V Instruction Manual

Hide thumbs Also See for ID-RP2010V:
Table of Contents

Advertisement

■ Cleaning

DO NOT use harsh solvents such as
benzine or alcohol when cleaning,
because they will damage the repeater
surfaces.
If the repeater becomes dusty or dirty,
wipe it clean with a dry, soft cloth.

■ Replacing fuses

If a fuse blows, or the repeater stops functioning, find
and repair the cause of the problem. Then replace the
damaged fuse with a new, adequately rated fuse.
L Spare fuses are supplied with the repeater.
The fuses are installed in the DC power cable and in
the inside circuitry, to protect the repeater.
• DC power cable fuses:
• Circuitry fuse:
R
WARNING!
• NEVER use fuses that are not specified. It may
damage the repeater or cause fire.
• Disconnect the DC power cable from the repeater
before replacing the fuse. Otherwise, it may
damage the repeater or cause an electrical shock.

D Replacing DC power cable fuses

Replace fuses as shown below.
1
2
ATC 25 A (ID-RP2010V)
ATC 10 A (ID-RP4010V/
ID-RP1200VD)
APS 5 A
3

MAINTENANCE

D Replacing the circuity fuse

Open the repeater main unit, and then replace the
fuse as shown below.
1. Remove the screws, and then remove the top
cover.
2. Remove the shield screws and springs*, and then
remove the shield cover.
* Some repeater may include springs. Confirm they are
in the same position when reattaching.
3. Replace the circuitry fuse as shown below.
CAUTION: Remove the fuse using needle-nose
pliers to protect your fingers and the fuse holders.
4. Reattach the removed parts.
12