Double Sensor Level - Amrotec MIB-9 Service Manual

Hide thumbs Also See for MIB-9:
Table of Contents

Advertisement

CURRENCY DISCRIMINATION COUNTER
Step 4. After adjustment is done, check if Solenoid normally works in 'Selector Test ' Mode.
( Press : '9'→'MODE'→ '*****' →'DISPLAY' →'4')

11-4. Double Sensor Level

DOUBLE LOGIC TEST
With this mode, you can check the double level.
Before you select
this mode, clean the all notes in the path and close all doors and run the motor more than 5 sec.
Press 'Menu'  'Mode'  '*****'  '1.Sensor Test'  '4. Double logic
test'.
You need to set the double level to '550' (± 50) turning the variable resisters.
< Old PBA Version >
"Old MTU (PBA_MIB-9_MTU_V0.6)" and "Old Main (MIB-9 MAIN_V0.3)"
Or "Old MTU (PBA_MIB-9_MTU_V0.6)"
and "New Main (MIB-9 MAIN_V1.0)"
 VR (variable Resister) is located on
the 'MTU board'
Step 3. Tighten SCREW (A) as the image on the left side.
At this time, the axis ('C') of SOLENOID should be
C
B
placed in the center of the hole ('B') in BKT
SELECTOR.
A
MIB-9 SERVICE MANUAL
DOUBLE TEST
CH LEFT :
550
CH RIGHT :
550
- 49 -