CURRENCY DISCRIMINATION COUNTER
Reject sensor is
covered
Stacker sensor is
covered
4) DOUBLE LOGIC TEST
With this menu, you can check the double level.
Before you select
this mode, you need to check bellows.
Clean inside of the double sensors and the path of note.
Close the upper door and rear door well.
Please run the motor more than 5 sec.
Both left and right channel need to adjust '550' (± 50).
For more detail information, please refer to the "Chapter11. ADJUSTMENT (Double sensor level)"
2. KEY TEST
PRESS ANY KEY
3. MOTOR TEST
MOTOR TEST
1.MAIN 1000 RPM ON
2.MAIN 1200 RPM ON
3.MAIN 1500 RPM ON
4.MAIN_FEED 1000 RPM ON
5.MAIN_FEED 1200 RPM ON
6.MAIN_FEED 1500 RPM ON
7.WING MOTOR ON
8. MOTOR STOP
LEFT
RIGHT
JP
0
0
SP
0
0
FRONT
0
REAR
0
0
REJECT F
1
STACKER
0
LEFT
RIGHT
JP
0
0
SP
0
0
FRONT
0
REAR
0
0
REJECT F
0
STACKER
1
In this mode, you can have a test if the machine detects the
input of key. Every time you press a key, the name of the key
will be displayed on LCD. However, in case of CLEAR key,
you exit from the current menu in stead of displaying.
After you push the "start" button, and press 9(menu) key, you
can exit from the current menu.
You can run Main and(or) Feed Motor in various speeds.
MIB-9 SERVICE MANUAL
DOUBLE TEST
CH LEFT :
550
CH RIGHT :
550