Amrotec MIB-9 Service Manual page 22

Hide thumbs Also See for MIB-9:
Table of Contents

Advertisement

CURRENCY DISCRIMINATION COUNTER
4. SET A/S CALL No.
A/S
NO. SETTIMG
_
PRESS START TO SAVE
5. SET MACHINE S/N
SET MACHINE S/N
1. S/N DISPLAY
2. S/N SETTING
6. CALIBRATION
CALIBRATION
1. CIS
2. IR
3. UV
4. MR & DOUBLE
5. HOPPER
6. SOLENOID
What is
CALIBRATION
the machine rejects too many notes, the system might not analyze the input of waveform.
It is possible to make a standard waveform for the system.
For more detail information, please refer to the "Chapter 9. CALIBRATION"
7. SENSOR SELECT
SENSOR SELECT
1. UV
2. MR
3. IR
- 22 -
After the machine is turned on, A/S call no. is displayed on LCD. In
this mode, you can set the telephone no. It is available up to 20
characters by using Numeric Key and then press START key to
save it.
UP key - Back Space
DOWN key – Used as Right key
1)
You can check the serial no. of the machine.
(In order that S/N is displayed correctly, S/N should be input first in
S/N Setting menu.)
2)
You can input the serial no. of the machine. It is available up to 20
characters by using Numeric Key.
UP key - Back Space
DOWN key – Used as Right key
In order that a system analyzes Reference Level and
a signal of the machine, the system should know the
full swing of a waveform of a signal.
?
CALIBRATION
is to make a full swing reference waveform to read the full level of a signal. If
UV, MR, IR: If you want to turn on or off sensor, you can do
ON
that in this mode.
ON
Select menu by using UP/DOWN and change ON/OFF by
ON
using START key.
MIB-9 SERVICE MANUAL
S/N Display
S/N Setting