CURRENCY DISCRIMINATION COUNTER
9 MENU
3
CALIBRATION
1. CIS
2. IR
3. UV
4. MR & DOUBLE
5. HOPPER
6. SOLENOID
Wait.
UV SHADING
WAIT . . ABOUT 5 SEC
After check shading result, press clear button.
If you want to move previous Level, press '9'.
- 34 -
MODE
MIB-9 SERVICE MANUAL
CODE [ ***** ]
6
SERVICE MENU1
1.ERROR STOP CTRL.
2.REJECT DETAIL ON/OFF
3.SYSTEM REPORT
4.SET A/S CALL NO.
5.SET MACHINE S/N
6. CALIBRATION
7. SENSOR SELECT
8. SYSTEM SETTING
Shading sheet is pushed out.
If shading of each currency is
done normally,
OK is displayed.
UV SHADING
ON LEVEL : 3049
828
OFF LEVEL : 3184
750
UV (OK)
UVR (OK)