Solenoid - Amrotec MIB-9 Service Manual

Hide thumbs Also See for MIB-9:
Table of Contents

Advertisement

CURRENCY DISCRIMINATION COUNTER

9-6. SOLENOID

9 MENU
5
CALIBRATION
1. CIS
2. IR
3. UV
4. MR & DOUBLE
5. HOPPER
6. SOLENOID
Machine will display as below picture.
SOLENOID CALIBRATION
1.
STACKER
2.
REJECTOR
SOLENOID DRIVING TIME
: 7740US
PRESS START TO STORE
- 38 -
MODE
Press key '1' and '2'
Machine will display the 'DRIVING TIME'.
If the 'Solenoid Driving Time' shows result in red, you
need to check the assembly status.
This menu is only for test.
MIB-9 SERVICE MANUAL
CODE [*****]
6
SERVICE MENU1
1.ERROR STOP CTRL.
2.REJECT DETAIL ON/OFF
3.SYSTEM REPORT
4.SET A/S CALL NO.
5.SET MACHINE S/N
6. CALIBRATION
7. SENSOR SELECT
8. SYSTEM SETTING