Amrotec MIB-9 Service Manual page 26

Hide thumbs Also See for MIB-9:
Table of Contents

Advertisement

CURRENCY DISCRIMINATION COUNTER
1. SENSOR TEST
1) LED TEST
Turn ON/OFF LED.
IR sensors such as JP, SP, Hopper, Reject and Stacker sensors are
invisible using human eyes. You can check these lights using Phone
camera.
2) HOPPER TEST
In this mode, the level of HOPPER is displayed.
The machine will start counting in below condition.
'HOPPER OFF' should lower than '32' with banknote on the hopper.
3) SENSOR LOGIC TEST
In this mode, you can check if the sensor is defective or not by checking detected logic status of each sensor. The
below pictures show logic status when the sensor is covered or open by note.
CASE
All doors are closed.
Upper Door is open.
Rear Door is open.
Front and Rear Door
are open.
- 26 -
LCD DISPLAY
LEFT
RIGHT
JP
0
0
SP
0
0
FRONT
0
REAR
0
0
REJECT F
0
STACKER
0
LEFT
RIGHT
JP
1
1
SP
0
0
FRONT
1
REAR
0
0
REJECT F
0
STACKER
0
LEFT
RIGHT
JP
0
0
SP
1
1
FRONT
0
REAR
0
1
REJECT F
0
STACKER
0
LEFT
RIGHT
JP
1
1
SP
1
1
FRONT
1
REAR
0
1
REJECT F
0
STACKER
0
MIB-9 SERVICE MANUAL
SENSOR TEST
1. LED TEST
2. HOPPER TEST
3. SENSOR LOGIC TEST
4. DOUBLE LOGIC TEST
HOPPER ON : 250
HOPPER OFF :
25
DIFFERENCE : 225
PICTURE

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Amrotec MIB-9

Table of Contents