11. Diagnose a fault

A list of fault conditions and their possible causes is provided here to assist in basic
troubleshooting. If you are unable to rectify a fault using this guide, call your supplier or your
nearest Edwards Service Centre for advice.
Fault

Pump does not start up

Cause
Motor incorrectly connected.
Remedy
Connect motor correctly.
Cause
Overtemperature switch or motor stator defective.
Remedy
Contact Edwards Service.
Cause
Pressure switch is defective.
Remedy
Replace the pressure switch.
Cause
Lubricant is too thick.
Remedy
Exchange the lubricant or warm up lubricant and pump.
Cause
Motor rotor defective.
Remedy
Contact Edwards Service.
Cause
Pump has seized: defective rotors, bearings or toothed gears.
Remedy
Contact Edwards Service.
Fault

Pump gets too hot

Cause
Cooling-water supply is not sufficient.
Remedy
Ensure sufficient cooling-water supply.
Cause
Cooling-water lines are clogged.
Remedy
Decalcify cooling-water lines.
Cause
Ambient temperature is too high or cooling air flow is obstructed.
Remedy
Install the pump at a suitable place or ensure a sufficient flow of cooling air.
Cause
Pump is operating in the wrong pressure range.
Remedy
Check the pressure levels within the system.
Cause
Gas temperature is too high.
Remedy
Check system.
Cause
Clearance between housing and rotors are too small due to contamination.
Remedy
Clean pumping chamber.
Cause
Clearance between housing and rotors are too small due to distortion of the pump.
Affix and connect the pump free of tension.
Remedy
A41802880_C - Diagnose a fault