its quality.
The specifications, quantity, routing direction, and placement position of
the required cables should conform to the construction drawing design
requirements. The wiring length of each cable should be determined according
to the actual location.
The user cable is placed separately from the power cable.
There shall be no broken wires in the middle of the laid cables or joints in
the middle.
The cable should be straight and tidy in the aisle, and the turn should be
even, smooth and straight.
The cable should be straight in the channel, and should not be out of the
channel, blocking other access holes, and should be tied and fixed at the cable
exit channel or cable bend.
When the cable, power cable, and ground cable are placed in the same
slot, the cable, power cable, and ground cable cannot overlap and mix.When
the cable is too long, the cable grounding plate must be placed in the middle of
the cable tray and cannot be pressed on other cables.
When the tail fiber is laid, it is necessary to prevent the cable from being
knotted and the turning point should be minimized, and the turning radius
should not be too small.The lashing should be tight and not too tight.When
laying on the cable rack, it should be placed separately from other cables.
The two ends of the cable should have corresponding identifiers. The
content of the identification is concise and easy to maintain.
Attention
When laying the pigtail, it is necessary to prevent the cable from being
knotted and the turning point should be minimized, and the turning radius
should not be too small. If the turning radius is too small, the link optical
signal will be seriously depleted.Affect the quality of communication.

2.3. Simple Test

2.3.1. System Self-test

When the device is powered on, all service port indicators on the front
panel will flash once, indicating that the port is working properly.After that, the
corresponding Power will be always on, and the Run light (system running
status indicator) will flash periodically at intervals of 1s.

2.3.2. Tx Port Test

As shown in FIGS.2-15,the device is working with power supply, arbitrary
ports are connected by two network port electrically straight-through cable and
two test computers, sending Ping command to each other,both sides can
- 12 -