Page 3
MIEN5208 Series Managed Industrial Ethernet Switch Revise history: Version Date Reason V1.0 2016.09 Create files Added the import and export function of RSTP and configuration V2.0 2018.03 files.Modify QOS and VLAN function...
Page 4
MIEN5208 Series Managed Industrial Ethernet Switch Safe Use Instruction This product performance is excellent and reliable in the designed range of use, but it’s necessary to avoid man-made damage or destroy for the equipment. Read the manual carefully and keep this manual for reference if need afterwards.
MIEN5208 Series Managed Industrial Ethernet Switch 1. Introduction 1.1. Product introduction Wuhan Maiwe industrial Ethernet switch is specially designed for industrial high speed communications network. It provides the advanced industrial Ethernet solution, which makes the industrial communications more fluent, dependable and fast..
MIEN5208 Series Managed Industrial Ethernet Switch work reliably in the environment of -40 ° C ~ +85 ° C High-strength enclosed aluminum housing allows the system to work reliably in harsh and dangerous industrial environments Standard products are DIN rail mounted, and it can also provide other accessories required for installation.
After long press for 5s, the device will automatically restore the factory settings. 3.1.2. LED indicator lights The LED indicators on the front panel of the MIEN5208 series switch can show the status of the system operation and port, which is easy to find and solve the fault.
3.1.3. Hardware installation Din-rail installation If the MIEN5208 series switch needs to be snapped onto the DIN rail, the DIN rail should be checked for installation before installation. Includes the following 2 items: Weather the DIN rail fixed and strong, whether other equipment is installed on the DIN rail, and whether there is enough space for installing the switch.
When all other cables are connected, you can connect to the power supply. 3.1.5. Fiber connection The 2 fiber ports + 6 copper ports version of the MIEN5208 series switches offer 100Base-FX full-duplex single-mode or multimode fiber interfaces. The type of fiber optic interface can be selected according to the needs of SC / ST / FC.
10M state), and the green light on the corresponding port should flash. The hardware of the two electrical ports tested is working properly. The following test diagram takes the 8-port product of the MIEN5208 series switch as an example.
MIEN5208 Series Managed Industrial Ethernet Switch port should flash, indicating that the two optical ports tested are working properly. Figure 3-5 shows the optical port test of the M light 5208 series switch. 3- 5 3.2.4. Networking topology Generally, the device requires three or more switches of the series to form a ring.
MIEN5208 Series Managed Industrial Ethernet Switch 4. Management function Statement The interface and configuration of all the following functions are subject to the actual product. The MIEN5208 100M Industrial Ethernet Switch Embedded Module has a built-in web server that provides a convenient way to access and configure the switch.
Page 17
MIEN5208 Series Managed Industrial Ethernet Switch There are three types of login users on this switch. The first type is a normal user. The user name and the initial password are both "admin". It is used when the web is accessed normally. The second type is the guest. The username and password are both "none".
MIEN5208 Series Managed Industrial Ethernet Switch page can be roughly divided into three areas, the upper area displays the logo, the lower left area is the function menu area, and the lower right area is the main function display area.
MIEN5208 Series Managed Industrial Ethernet Switch 4.2.2. Help files The top right of the main function area is the help link. Clicking “Help” on any page will bring up the help page of the current page function. 4.3. Equipment information 4.3.1.
MIEN5208 Series Managed Industrial Ethernet Switch Device Number: The number of the switch. MIEN5208 Series Industrial Ethernet Switch User Manual System time: The current time of the switch is synchronized with the time of the PC accessing the switch. Hardware version: The current hardware version of the switch.
Page 21
Automatic flip transform Statement: The MIEN5208 series managed industrial Ethernet switches provide web page function configuration. All configuration parameters will be submitted to the switch after clicking the configuration button. Before exiting this page, any changes made by the user will be canceled. Clicking the Cancel button will not submit the changes made by the user and restore the page to what it was before the modification.
MIEN5208 Series Managed Industrial Ethernet Switch Attention: 1.Auto-negotiation mode are all RJ-45 port default mode , when RJ-45 ports are all auto-negotiation mode , the connected equipment should also use auto-negotiation Mode, otherwise auto-negotiation failed the Ethernet switch ports will default half-duplex mode , lead to communication problem .
MIEN5208 Series Managed Industrial Ethernet Switch 4.The port speed limit requires high quality of the network cable, otherwise a large number of conflict packets and broken packets will appear. 4.6. Advanced function Advanced function include: Qos, VLAN, fast ring, multicast configuration, alarm configuration, and port mirroring.
VLAN (Virtual Local Area Network) refers to virtual local area network technology. VLAN is an effective means of network management, and can effectively suppress the occurrence of broadcast storms. The MIEN5208 series of managed industrial Ethernet switches support IEEE 802.1Q VLANs.
Page 25
MIEN5208 Series Managed Industrial Ethernet Switch Port number: The label of the switch port. There are 8 ports . PVID: The default VLAN ID of the port. The PVID of the access port is the same as the VLAN it allows to pass. The PVID of the trunk port and the hybrid port must be one of the VLANs it allows to pass.
PC must be added to the same VLAN as the pvid of the VLAN trunk port. 4.6.3. Fast Ring network Mwring technology is developed and designed by Wuhan Maiwe Communication Co., Ltd. for high reliability industrial control network applications. This technology allows switches to be connected by redundant links.
MIEN5208 Series Managed Industrial Ethernet Switch Ring port 1: Join the first port of the ring group. Ring 2: Join the second port of the ring group. Ring network type: The type of the ring network group, which is usually a single ring network.
MIEN5208 Series Managed Industrial Ethernet Switch Port list: Select the default forwarding port of the multicast packet whose destination address is this multicast MAC address. To which port to forward, you can tick it. Processing list: This column is used to operate the multicast table, buttons and to add and delete static MAC addresses.
MIEN5208 Series Managed Industrial Ethernet Switch mirroring, which copies packets from multiple ports to one monitoring port. You can also specify the direction of the monitored packets, such as monitoring only the packets sent by the specified port. Port mirroring: Enable or disable port mirroring, which is disabled by default.
Page 30
MIEN5208 Series Managed Industrial Ethernet Switch the link. Rapid Spanning Tree Protocol (RSTP): The Rapid Spanning Tree Protocol (RSTP) is defined in the IEEE 802.1w standard, As a supplement to the 802.1d standard. RSTP set:active / inactive Fast Spanning Tree function is disabled by...
Page 31
MIEN5208 Series Managed Industrial Ethernet Switch from other Ethernet switch, this data package valid time ,default figure is 20, default unit is second, figure scale is integer from 6~40. Time setting figure need below formula: 2*(forward delay-1)>= Maximum aging time RSTP status information: click RSTP current status button to check RSTP status information.
Page 32
MIEN5208 Series Managed Industrial Ethernet Switch Disabled: Disabled state, which means that this port is not connected, and the unconnected port is in this state. Discarding: Blocking state, at this time BPDU packets can be received, if no BPDU is received during the period, it will go to learning Status, the ports are all blocked when the link is just connected.
MIEN5208 Series Managed Industrial Ethernet Switch Attention: 1. The RSTP protocol is defined in the 802.1w standard and is an open standard protocol. The RSTP protocol of the switch produced by the company can be compatible with network devices that are not produced by the company but support the standard RSTP protocol.
MIEN5208 Series Managed Industrial Ethernet Switch IP address: An IP address is a 32-bit length address assigned to a device connected to the Internet. An IP address consists of two fields: a network number field (net-id) and a host number field (host-id). The IP address is assigned by the Network Information Center (NIC) of the US Defense Data Network.
MIEN5208 Series Managed Industrial Ethernet Switch to log in and modify the machine. The password is fixed to "admin" and the password is the last six digits of the local MAC address. (If you don't know the MAC address of this machine, you can log in as a guest first) The login password must be a legal character consisting of 4-12 English letters (case sensitive) and numbers.
Page 36
MIEN5208 Series Managed Industrial Ethernet Switch benefit of this feature is the ability to remotely reboot the switch, allowing users to remotely reboot as long as they have remote access to the switch. The device restore factory configuration:This function is used to restore the switch to the factory settings and automatically restart the switch.
Page 37
MIEN5208 Series Managed Industrial Ethernet Switch When using web upgrade, you cannot use different language versions of the image for cross-upgrade; the Chinese version can only be upgraded with the Chinese version of the image, and the English version can only be upgraded with the English version.
MIEN5208 Series Managed Industrial Ethernet Switch 5. Maintenance and service Since the date of product shipped, it provides five years warranty. In the warranty period, if there is any failure or functional product fails, it will repair or replace free of charge for users of the product. However, these commitments do not cover improper use, accidents, natural disasters, improper operation or improper installation caused the damage.
Page 39
WUHAN MAIWE COMMUNICATION CO.,LTD Add.:Building 2, Area E, Phase ii, Optical valley core center, No.52, Liufang road, East Lake Hi-tech Development Zone,Wuhan,China Phone: 027-87170215/16 Fax: +86-027-87170217 www.maiwe.com...
Need help?
Do you have a question about the MIEN5208 Series and is the answer not in the manual?
Questions and answers