CRYO-METER MBD series
 
 
 
 
 
 
 
We recommend that ALL customers be sure to follow all
rules and regulations such as Foreign Exchange and
Foreign Trade Law when exporting or reexporting our
products.
D/N.MGMBD01E,2018JE04
MBD-S / MBD-T
Instruction Manual
Export Control Policy
ULVAC CRYOGENICS INCORPORATED
 
 

Advertisement

Table of Contents
loading

Summary of Contents for Ulvac MBD Series

  • Page 1 CRYO-METER MBD series MBD-S / MBD-T   Instruction Manual                 Export Control Policy We recommend that ALL customers be sure to follow all rules and regulations such as Foreign Exchange and Foreign Trade Law when exporting or reexporting our products.
  • Page 3 As a general rule, diagnosis of failure should be done on site by customer. However, ULVAC CRYOGENICS or our service network can perform this service for an agreed fee upon the customer’s request. There will be no charge if the cause...
  • Page 4 ULVAC CRYOGENICS. (2) Damage during transportation When damage by delivery/transportation is admitted, the product will be repaired free of charge within the range of the guarantee expressed in the sales contract.
  • Page 5 2.3 Repair period after production is discontinued ULVAC CRYOGENICS shall accept product repairs for seven years after production of the product is discontinued. 3. Service Form After the products are delivered, please fill out the following information in the blanks. If you have any questions or technical problems please feel free to contact the nearest Customer Support Center or headquarters.
  • Page 6 (3) If you have any questions or comments on this document, please do not hesitate to contact us. The phone numbers of local customer support centers are listed at the end of this manual. ULVAC CRYOGENICS INCORPORATED...
  • Page 7 There is a danger of fire or burn injury. Explosive gas used. There is a risk of fire or explosion. Hazardous voltage . Electric shock may cause severe injury or loss of life. Hot heating part present. There is a risk of burn injury. MZ0F001E,2013OR03 ULVAC CRYOGENICS INCORPORATED...
  • Page 8 This page intentionally left blank ULVAC CRYOGENICS INCORPORATED...
  • Page 9 We will offer you Material Safety Data Sheet (called MSDS) of our products upon your request. If you have any questions, please contact our Service Engineering Division or the nearest customer support center. MZIW001E,2010.01 ULVAC CRYOGENICS INCORPORATED IW-1...
  • Page 10 This page intentionally left blank. IW-2 ULVAC CRYOGENICS INCORPORATED...
  • Page 11: Table Of Contents

    CRYO METER MBD Display ..............8 TABLES Table 2-1 Specifications ..................2 Table 3-1 Connectors Input/Output Pins ............... 3 Table 6-1 Troubleshooting List ................9 ULVAC CRYOGENICS INCORPORATED                          I   ...
  • Page 12: Table Of Contents

    Inspection and Adjustment of CRYO METER MBD series Please contact our technical service department when inspection and/or adjustment of CRYO METER MBD series are needed. No circuit or any other parts of this product may be changed and/or adjusted in any shape or form in any circumstances.
  • Page 13: Features And Types

    CRYO METER MBD series Instruction Manual Features and types CRYO METER MBD series is an accessory device for cryogenic thermal display. It can be used in combination with CRYO METER MBS-C or MBS, cryogenic thermocouple thermometer connected to UCI cryopump. The MBD inputs the analog output signal from MBS-C/MBS and displays cryopump 2nd stage temperature numerically.
  • Page 14: Specifications

    CRYO METER MBD series Instruction Manual < Note> Although just “MBD” means “MBD-S” at ordering, MBD is used as the name for both MBD-S and MBD-T when there is no need to distinguish between them in this instruction manual. Specifications...
  • Page 15: Connector Specifications

    CRYO METER MBD series Instruction Manual Power lamp K Digital temperature display 3-digit Figure 2-1 MBD Front Panel Connector Specifications Figure 3-1 MBD Rear Panel Table 3-1 Connectors Input/Output Pins Connectable  plug  Names  Receptacle Pins  Assignments  Functions  types      A ...
  • Page 16: Installation

    CRYO METER MBD series Instruction Manual Installation Follow the instruction below to install the MBD on your display panel with a clamp kit. After installing the MBD, connect cables to the MBD. A clamp kit and cables are provided with the MBD.   ...
  • Page 17: Figure 4-1 Wiring Of Mbd-S/Mbd-T And Mbs-C

    CRYO METER MBD series Instruction Manual ◆Wiring    After the MBD has been installed to the panel, connect the MBD to the MBS-C. [MBD - MBS-C connecting cable (MBD-HS30)] can be used for connecting MBD to MBS-C POWER and ANALOG OUT (I/O connectors). In this case, wiring of MBS-C RELAY and K(CA) needs to be done by users.
  • Page 18: Figure 4-2 Wiring Of Mbd-S/Mbd-T And Mbs

    CRYO METER MBD series Instruction Manual [Userʼs control panel] (*2) MBS-MBD connecting cable (5m) (*2) Twisted shielded cable POWER OUT POWER RELAY < 20K ANALOG IN > 280K Power cable (*2) Twisted shielded cable ANALOG MBD-S: AC100V Plug BD-T: Terminal connection (AC100-200V)
  • Page 19: Figure 4-3 Mbd-S/Mbd-T Power Supply Circuit

    CRYO METER MBD series Instruction Manual ◆Power connection and protection    Figure 4-3 is a MBD-S/MBD-T power supply examples and its connection. It is recommended to calculate the capacities of the step-down transformer and of branch circuit protector/fuse by formulas below.   ...
  • Page 20: Operation

    If any problem is found at an inspection, follow the troubleshooting procedures in the troubleshooting lists on page 13 and 14 or contact our customer support. troubleshooting lists on page 13 and 14 or contact our customer support. ULVAC CRYOGENICS INCORPORATED...
  • Page 21: Table 6-1 Troubleshooting List

    If the temperature and displayed number on MBD don’t match, there is a possibility of MBD failure. please contact our customer support for replacement of the product or refer to MBS - C manual to proceed troubleshooting. ULVAC CRYOGENICS INCORPORATED...
  • Page 22 DC power cable problem If there is no problem, there is a possibility of displayed. Power supply cord (Noise and / or surge) MBD failure. 2.MBD failure Please contact our customer support for replacement of the product. ULVAC CRYOGENICS INCORPORATED...
  • Page 23: Cryo Meter Mbd-S / Mbd-T Dimensions

    MBD CRYO-METER Instruction Manual ULVAC CRYOGENICS INCORPORATED...
  • Page 24 MBD CRYO-METER Instruction Manual This page intentionally left blank. ULVAC CRYOGENICS INCORPORATED...
  • Page 25 Tel : +81-6-6397-0112 Fax: +81-6-6397-0126 <Inquiries about cryostats or LN generators> Kyoto Factory 140-1,Megawa,Makishima-cho,Uji,kyoto,611-0041,Japan Tel : +81-774-28-5595 Fax: +81-774-20-2201 ULVAC CRYOGENICS KOREA INC. www.ulvac-cryo.co.kr 107, Hyeongoksandan-ro, Cheongbuk-Myeon, Pyeongtaek-si, Gyeonggi-Do, Korea, 451-831 Tel : +82-31-683-2926 Fax: +82-31-683-2956 ULVAC CRYOGENICS (NINGBO) INC. www.ulvac-cryo.com 1-2 Floor, Shuguang Building, No.6 Jingyua Road,...
  • Page 26 This page intentionally left blank. CS-2 ULVAC CRYOGENICS INCORPORATED...
  • Page 27 CRYO METER MBD series Instruction Manual Revision History Date Revision No. Contents 2007-12-10 2007.12 First edition 2008-04-11 2008AL01 Addition of the connector set in shipping list. 2009JE02 “Introduction” has revised. 2009-06-08 UCN address has changed. “SERVICE NETWORK” has revised. 2013-11-08 2013NR03 “Introduction”...
  • Page 28 Revision History This page intentionally left blank                                       ULVAC CRYOGENICS INCORPORATED...