Setting/Fine-Tuning Parameters Manually - Hanskamp Spider Installation And Operating Instructions Manual

Feeding computer
Table of Contents

Advertisement

EN
Feeding computer - Voercomputer - Fütterungscomputer - Logiciel d'alimentation

4.3.4 Setting/fine-tuning parameters manually

This menu contains a number of settings that are normally set correctly with tag tuning but may be changed manually here.
Id
Description
30011
Enable Tagtypes
30001
RFID: Frequency
30002
RFID: Multiplextime, the time an Antenna is active (not
30003
RFID: Holdtime, the maximum time between 2 reads
30007
RFID: LEDS on when detect (0=off/1=on)
30011 Enable Tagtypes: Specify the tagtype used. By adding up the values, multiple types of transponders can be
read. Contact Hanskamp for more information about the possibilities.
30001 RFID Frequency: Enter the best frequency for this tag in combination with the Antenna. To fine-tune,
increase and decrease this value in steps of 500 to find the best setting for your situation.
30002 RFID Multiplextime: This is the time frame within which the Antenna is active and ready to read the tag.
Only one Antenna will be active at a time. The value can be increased for slower transponders with a longer
loading time (e.g. for tagtype 16, the setting should be at 2000). This setting is not used for HDX or DeLaval. In that
situation, the Burst and Listentime must be set correctly.
30003 RFID Holdtime: This is the time frame within which the tag must be read again to confirm that the same
cow is still present. If the cow is not recognised every 3000 msec, this time can be increased to allow the feeding
process to continue during Holdtime. If no cow is identified during Holdtime, the feeding process will stop.
30007 RFID LEDS: Set to 1, to activate an extra 'service' function in the LED indicator. On the front of the Spider
unit, the LED corresponding to the active Antenna turns red. When a transponder is detected, the LED will light
up/flash green. This is handy for testing and fine-tuning the Antennas. This setting is set to 0 by default to keep the
LED indicator clear.
Check 'Advanced settings' to view and change more settings.
Index
Hanskamp AgroTech B.V. (The Netherlands)
Value
2
Tagtypes:
HDX=1
FDX_B=2
DELAVAL=4
EM410x=8
NEDAP 1st gen=16
NEDAP 2nd
gen=32
VCODE=64
ID2000=128
FULLWOOD=256
ALL=4294967295
Combi: HDX(1)+DELAVAL(4)=5
134200
300
3000
0
26 - 46