Field Startup Group:
Menu item
1
Keypad/Display Lock Feature Enable
2
Menu Settings Password Enable
3
ICS Address:
4
Power Up Start Delay Time
5
Design Delta Temp Setpoint:
6
Lvg Wtr Temp Cutout Setpoint:(When this setpoint is
within 1.7° F of the Front Panel Chilled Water Setpoint,
the Front Panel Chilled Water Setpoint is increased
along with this setpoint to maintain the differential)
7
Low Rfgt Temp Cutout Setpt: (When this setpoint is
within 6° F of the Front Panel Chilled Water Setpoint,
the Front Panel Chilled Water Setpoint is increased
along with this setpoint to maintain the differential.)
8
Condenser Limit Setpoint:
9
Maximum Rl Timer Setting
10
Purge Control/Type:
11
Purge Max Pumpout Rate:
12
Purge Service Excessive Pumpout Override Timer
13
Prg Low Liq Temp Inhibit
14
Prg Low Liq Temp Inhibit Setpt: (Does not display
unless above feature = "Enable")
15
Surge Protection:
16
Under/Over Voltage Protection: (Permits "Enable only if
Option Installed)
17
Phase Reversal Protection:
18
Phase Unbalance Protection:
19
Momentary Power Loss Protection:
20
Enhanced Oil Temp Protection
21
Oil Temp Setpoint:
22
Low Oil Temp Cutout:
23
High Discharge Temp Cutout:
24
Soft Load Control:
25
Soft Load Starting current Limit:
26
Soft Load Current Limit Rate:
27
Soft Load Lvg Water Rate:
28
Hot Gas Bypass Control
29
HGBP Timer
30
Maximum HGBP Time (Displayed only if HGBP is
installed and HGBP Timer is enabled)
14
FastPak
"Settings Group" Menu Record
Choices
Disable, Enable
Disable, Enable
1 to 127
0 to 600 Seconds
4 to 30° F, 2.2 to 16.7° C
-10 to 36° F,
-23.2 to 2.2° C
-35 to 36° F,
-37.2 to 2.2° C
80 to120 %
30 to 60 Minutes
Micro Purge, Stand-Alone Purge
1 to 100 minutes/24 hrs
1 to 72 Hours
Enable, Disable
32 to 50 °F, 0.0 to 10 °C
Disable, Enable
Disable, Enable
Disable, Enable
Disable, Enable
Disable, Enable
Disable, Enable
100 to 160° F, 37.8 to 71.1° C
80 to 140 °F, 26.7 to 60° C
170 to 220 °F, 76.6 to 104.4 °C
Disable, Enable
40 to 100 %
0.5 to 5.0 % /Minute
0.5 to 5.0 °F/Minute
°C/Minute
Disable, Enable
Disable, Enable; Unlimited Time
1 to 480 minutes
Default
Disable
Disable
65
0 Seconds
10° F, 5.5 ° C
36° F, 2.2° C
32° F, 0.0°C
93%
60 Minutes
Micro Purge
20 Minutes /24 Hours
0 Hours
Disable
40 ° F, 4.4 ° C
Enable
Enable
Enable
Enable
Enable
Enable
143.5 °F,61.9 °C
95 °F, 35 °C
200 °F, 93.3 °C
Disable
100 %
5.0 % /Minute
5.0 °F/Minute
0.3 to 2.8
°C/Minute
Enable
Enable
30 minutes
Design/Actual
2.8
CVRC-M-1D