Trane TCONT402AN32DA Owner's Manual
Trane TCONT402AN32DA Owner's Manual

Trane TCONT402AN32DA Owner's Manual

Comfort control
Hide thumbs Also See for TCONT402AN32DA:

Advertisement

XR402
Comfort
Control
TCONT402AN32DA
Comfort Control
$
Owner's Manual
Fan
Mode
Filter/OD

Advertisement

Table of Contents
loading

Summary of Contents for Trane TCONT402AN32DA

  • Page 1 XR402 Comfort Control TCONT402AN32DA Comfort Control Owner’s Manual Mode Filter/OD...
  • Page 2 Table Of Page Introduction Contents 4-10 Keypad functions 12-16 Features Factory settings 18-19 Comfort Control Setup Up Arrow - Increase 20-21 Troubleshooting temperature Page 5. 22-23 Warranty Comfort Information Drawer Page 16. Down Arrow - Decrease Filter/OD Mode temperature Page 5. Mode: Cool, Heat, Energy Savings Auto, Off, EMHeat...
  • Page 3: Warranty

    Low Voltage Room Comfort Controls arts Subject to the terms and conditions of this limited warranty, Trane U.S., maintenance, or operation including, but not limited to, operation of electri- Inc. (“Company’) extends a limited warranty against manufacturing defects for the cal equipment at voltages other than the range specified on the Product product(s) identified in Table 1A attached hereto (“Products’) that are installed in a...
  • Page 4: Keypad Functions

    Keypad MODE Functions - Pressing this key changes the system mode to Heat, Cool, Automatic or Off. Mode A border will appear around the mode on the display to show the system mode you’ve selected. Mode Page - 4 Pub. No. 22-5209-04 Table 2 Troubleshooting (Continued) Symptom...
  • Page 5: Troubleshooting

    Table 2 Troubleshooting Trouble Symptom Possible Cause Action 1. Blown fuse or tripped circuit breaker. 1. Replace fuse or reset breaker. -shooting 2. Furnace power switch OFF. 2. Turn switch to ON. Display will not come on. 3. Furnace blower compartment door or 3.
  • Page 6: Lock - Unlock Keypad

    Keypad Functions (cont-) - Pressing this key selects whether the indoor fan motor runs in automatic or con- tinuous mode. The FAN ON indicates that you have selected to oper- ate the fan in continuous mode. Pressing the Fan keypad button again returns the in- door fan mode of operation to automatic and FAN ON goes away.
  • Page 7: User Setup

    User Entering User Setup: Setup Press and hold the MODE and FAN keypad buttons at the same time. Options Keypad Navigation: - Use the MODE or FAN buttons to navigate forward and backward through the Setup steps. - Press MODE to advance forward to the next step. - Press FAN to return to the previous step.
  • Page 8 Keypad FILTER/OD Functions - Press this key twice to display how many days remain before time to replace or (cont-) Filter/OD clean the filter. The “FILTER/OD” indicator will flash on the display when the filter timers days remaining reaches zero. Filter/OD - Press the “FILTER/OD”...
  • Page 9 Features Calibrate Outdoor Temperature This option allows calibration (or deliberate miscalibration) of the outdoor temperature (cont-) sensor. The selected number is number of degrees, plus or minus, which will be added to actual temperature. The number can range between + 5 and - 5 degrees in 1/2 degree increments.
  • Page 10: Service Indicator

    Keypad Energy Savings Functions (cont-) - Use this key to lower your systems energy consumption and save money at the same time! Pressing the Energy Savings keypad button changes the indoor tem- perature setting to a warmer temperature when the system is operating in the cool- ing mode and to a cooler indoor temperature setting when operating in the heating mode.
  • Page 11: Filter Reminder

    Filter Reminder Features “FILTER/OD” will automatically flash to remind the homeowner that its time to (cont-) change the filter once the preset time has expired. Pressing the “FILTER/OD” keypad button automatically resets the internal clock timer. Once the timer has been reset, the number of days remaining till the next filter change can easily be determined by simply pressing the “FILTER/OD”...
  • Page 12 Auto Changeover When the system mode is set to Auto, the control automatically switches between heat- Features ing and cooling modes to maintain the desired comfort level. Appears when equipment is energized. Adjusting to new setting Setpoint Deadband The number of degrees separating Heating and Cooling setpoints. Neither the heating or cooling system operate when the indoor temperature is within the deadband.

Table of Contents