12 Disconnect the AC power. Reconnect the AC power and measure the voltages in Table 7.3. The
voltages must be measured during the first 9 seconds after AC power is applied, with the Main
Drive Motor running. All the voltages in column 5 (interlock closed 1 to 9 seconds) are correct.
Y
N
|
Replace the Engine PWB (PL 7).
13 Replace the Main Drive Motor Assembly (PL 6).
Measure Voltage
from CN1 Pin
3
4
5
6
Xerox DocuPrint P1202 Service Manual
Table 7.3. Main Drive Motor Voltages
To
Interlock Open
Frame Ground
24.4 +/- 2.0 VDC
Frame Ground
24.4 +/- 2.0 VDC
Frame Ground
24.4 +/- 2.0 VDC
Frame Ground
24.4 +/- 2.0 VDC
3/99
www.printcopy.info
Interlock Closed
(after 10 Seconds)
23.8 +/- 0.5 VDC
23.8 +/- 0.5 VDC
23.8 +/- 0.5 VDC
23.8 +/- 0.5 VDC
7-7
Repair Analysis Procedures (RAP)
Interlock Closed
(1 to 9 Seconds)
21.8 +/- 1.0 VDC
21.8 +/- 1.0 VDC
21.8 +/- 1.0 VDC
21.8 +/- 1.0 VDC