Technical Data - RK Rose+Krieger RK MultiControl II duo Assembly Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Technical data

10

Technical data

Exceeding the load specifications
MultiControl II duo/quadro
Properties
Dimensions
Weight
Supply voltage (primary)
Maximum current consumption (pri-
mary)
Nominal power
Standby input power*
Maximum number of drives
Maximum output current
Nominal and output voltage
Duty cycle (DC)
Protection class
Protection rating
Room temperature
Air pressure
Relative air humidity
222
MultiControl II duo
with nominal load 20% DC:
Example: 20 min cycle time (4 min operating time, 16 min rest time)
* Standby input power is higher in combination with Multilift I/Multilift synchron
Control unit RK MultiControl II duo/RK MultiControl II quadro
NOTICE!
Material damage due to load specifications
being exceeded!
If the load specifications defined by RK Rose
+Krieger GmbH are exceeded, there is a risk of
personal injury and material damage.
– Never exceed the load specifications.
240 mm x 105 mm x 56 mm
800 g
100 - 240 VAC, 50/60 Hz
3.5 A at 100 VAC
3.0 A at 115 VAC
1.5 A at 230 VAC
350 VA
< 0.5 W
2
5 A per drive, 10 A total
28.5 VDC ± 2%
I, secondary SELV
IP20
+5°C - +40°C
700 hPa - 1600 hPa
30% - 75%
MultiControl II quadro
1000 g
< 1.0 W
4
20.08.2021