2. WIRING
2.4

Radar Connection Box RCB-002 (Optional)

The RCB-002 is capable of connecting the FMD-3100 with up to two external radar
systems. Referring to the figure and table below, connect the respective equipment to
the RCB-002.
NETWORK
To HUB-3000
MOD-Z072 cable
Connecting LAN cables
When connecting LAN cables (MOD-Z072) to the RCB-002, use the following
procedure.
1. Unfasten and remove the sealing nut from the NETWORK port on the RCB-002,
then remove the seal assembly. See the figure below for reference.
2-28
RADAR SIGNAL IN No.1
To external radar
MJ-A10SPF0020A (5m, 10 m, 20 m, 30 m) cable
RADAR SIGNAL IN No.2
To external radar
MJ-A10SPF0020A (5m, 10 m, 20 m, 30 m) cable
POWER
To PR-240/241
MJ-A3SPF cable
Unused
Seal assembly
Seal nut
To ship`s ground
Ground cable, IV-1.25sq.
Seal
Claw