2.1.5
Fabricating, connecting TTYCSLA cable (JIS cable)
How to fabricate the TTYCSLA cable
Fabricate the TTYCSLA cables as shown below to connect them to the terminal block
on the PCU-3010 (See the following page for how to connect wires to the terminal
block.)
After fabricating the cable, attach the terminal block and EMI ferrite core (supplied).
For how to attach the connector mount and EMI ferrite core, see the next page.
Armor
* For flush mount installation, the length should be
based on the installation location.
Vinyl tape (Width: 20)
Clamp here with cable clamp.
How to attach the rod terminal
After attaching the rod terminal, use a crimping
tool (CRIMPFOX 10S, option) to crimp.
For flush mounted installations, connect the drain wires to respective terminal.
Connect drain wire of
C3 and C4 here.
100*
5
Sheath
Drain wire
250*
80
Pass a heat shrink tube (local supply) onto the
drain wire, then attach the crimp-on lug (supplied
with the PCU-3010) to it.
0.5 to 1 mm
The core must protrude 0.5 to 1 mm
past the rod terminal.
6
Crimp-on lug (supplied)
Attach rod terminal ( type AI
0.75-6 GY) to each wire as
shown below.
Connect drain wire of
C1 and C2 here.
2. WIRING
2-9