1. MOUNTING
1.1.1
Flush mounting
You will need a Torx screwdriver (T10, T25) to complete this procedure.
1. Attach the USB cable clamp to the PCU using the Torx screws supplied.
USB cable clamp
2. Make a cutout in the mounting location, referring to the outline drawings at the
back of this manual.
3. Connect all cables to their appropriate slot on the PCU. Take care to leave enough
slack in the cables to allow access for maintenance and repair.
4. Slide the unit into the cutout. Take care to not to bend or squash any cabling.
Note: User controls and ports should be facing downwards.
5. Taking care not to confuse the bracket types (see figure below), fasten each
bracket into place, referring to the figure below.
: Flush mount bracket
: Flush mount bracket
• "A" flush mount bracket: Use pan head screws
(M5×16) and C washer.
• "B" flush mount bracket: Use flat head screws
(M5×16). Only the "B" flush mount bracket (for the
lower part) has different lengths and screw holes.
1-2
Mounting hole
Mounting hole
Panel PC
Pan head
screw
C washer
Flush mount
bracket
Installation side (rear side)
Attach the
USB cable
clamp to
these posts.
Flat head
screw
Flush mount bracket
Flush mount bracket