12 Maintaining and
cleaning
before doing any technical work on the
device, disconnect the power supply.

12.1 Maintaining

Maintenance must be carried out by
personnel trained to operate on electrical
circuits.

12.1.1 Fuses replacement

Maintenance must be performed with the
power supply disconnected and the circuit-
breaker open.
F2
Fig. 83
40
F1
FUSES REPLACEMENT
Voltage
Fuse F1
24Vac, 50/60Hz
F 6.3A L 250V 5x20
120Vac, 50/60Hz
F 6.3A L 250V 5x20
230Vac, 50/60Hz
F 6.3A L 250V 5x20
Tab. 9
Fuse F2
T 8A H 250V 5x20
T 4A H 250V 5x20
T 2A H 250V 5x20