Connection Of The 24Vac Power Supply Line; Connection Of The 120/230Vac Power Supply Line - Videotec ULISSE NETCAM Instruction Manual

Uuunit fot network cameras
Hide thumbs Also See for ULISSE NETCAM:
Table of Contents

Advertisement

Available languages

Available languages

7.2.3.2 Connection of the 24Vac power
supply line
Only for products marked UL intended for
the North American market, use a class 2 UL
listed transformer.
Power the device with an SELV type, 24Vac,
8A isolated source derived from a double
isolation UL Listed transformer specially
protected in output. Alternatively, use the
UPTIRPS120 power supply and control kit.
24Vac
GND
a
Fig. 40
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 24Vac
Defined by the installer
Defined by the installer
Yellow/Green
Tab. 5
26
CN1
24Vac
Terminals
24Vac
24Vac
GND
7.2.3.3 Connection of the 120/230Vac power
supply line
To connect the power supply line use the
appropriate junction-box (UPTjbUL). For
further information, refer to the product
use and installation manual.
N
GND
a
Fig. 41
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 230Vac
Blue
Brown
Yellow/Green
Power supply 120Vac
Blue
Brown
Yellow/Green
Tab. 6
CN1
L
Terminals
N (Neutral)
L (Phase)
GND
N (Neutral)
L (Phase)
GND