Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0222
User Action:
If the NMI button on the operator information panel has not been pressed, complete the following steps:
1. Reseat the identified compute node.
2. If the problem still exist, replace the compute node.
3. (Trained technician only)Replace the system board. Reseat the identified compute node.
4. If error still exist, then replace compute node.
• FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Timeout.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0224
User Action:
Please reseat the processor and reboot the compute node. If the problem still exist, please replace the
identified processor in the compute node.
• FQXSPIO0006N: A software NMI has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Software NMI.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0228
User Action:
Check the event log in system management module (SMM) to resolve any issues related the NMI
• FQXSPIO0011N: An Uncorrectable Error has occurred on [SensorElementName].
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0240
User Action:
Check http://support.lenovo.com/ for TECH tips or firmware updates that might correct the error.