The power supply experiences an internal fault caused overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
– If AC LED is not lit, check power cord and input voltage.
– If DC LED is not lit, remove and reinstall power supply.
– If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
• 086F01AD: PS2_INTRL_OC_ERR: Power Supply, Power Supply Failure detected was asserted.
The power supply experiences an internal fault caused overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
– If AC LED is not lit, check power cord and input voltage.
– If DC LED is not lit, remove and reinstall power supply.
– If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
• 086F01AE: PS1_INTRMTNT_ERR: Power Supply, Power Supply Failure detected was asserted.
The power supply experiences an internal fault/non-overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
– If AC LED is not lit, check power cord and input voltage.
– If DC LED is not lit, remove and reinstall power supply.
– If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
• 086F01AF: PS2_INTRMTNT_ERR: Power Supply, Power Supply Failure detected was asserted.
The power supply experiences an internal fault/non-overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
– If AC LED is not lit, check power cord and input voltage.
– If DC LED is not lit, remove and reinstall power supply.
– If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
• 086F03E0: PS1: Power Supply, Power Supply input lost (AC/DC) was asserted.
The line cord input of indicated PSU is lost
Severity: Critical
User Action:
Information only; no action is required.
• 086F03E1: PS2: Power Supply, Power Supply input lost (AC/DC) was asserted.
The line cord input of indicated PSU is lost
.