The BMC has no response over 7 minutes after the client OS is power on, no further action will be taken.
Severity: Critical
User Action:
1. Please shutdown the OS
2. Reset the XCC
3. Check the SEL if other Fail-Safe SEL asserted
• 2107066B: NODE4_FS_NORESP: Slot Or Connector, transition to Non-recoverable was asserted.
The BMC has no response over 7 minutes after the client OS is power on, no further action will be taken.
Severity: Critical
User Action:
1. Please shutdown the OS
2. Reset the XCC
3. Check the SEL if other Fail-Safe SEL asserted
• 21070670: NODE1_FS_NOPERM: Slot Or Connector, transition to Non-recoverable was asserted.
The BMC has no response over 14 minutes and the client OS is power off, the allocated power budget has
be retrieved and the power permission and the power permission has been rejected.
Severity: Critical
User Action:
Replace the compute node (For more detailed information, please refer to Maintenance Manual)
• 21070671: NODE2_FS_NOPERM: Slot Or Connector, transition to Non-recoverable was asserted.
The BMC has no response over 14 minutes and the client OS is power off, the allocated power budget has
be retrieved and the power permission and the power permission has been rejected.
Severity: Critical
User Action:
Replace the compute node (For more detailed information, please refer to Maintenance Manual)
• 21070672: NODE3_FS_NOPERM: Slot Or Connector, transition to Non-recoverable was asserted.
The BMC has no response over 14 minutes and the client OS is power off, the allocated power budget has
be retrieved and the power permission and the power permission has been rejected.
Severity: Critical
User Action:
Replace the compute node (For more detailed information, please refer to Maintenance Manual)
• 21070673: NODE4_FS_NOPERM: Slot Or Connector, transition to Non-recoverable was asserted.
The BMC has no response over 14 minutes and the client OS is power off, the allocated power budget has
be retrieved and the power permission and the power permission has been rejected.
Severity: Critical
User Action:
Replace the compute node (For more detailed information, please refer to Maintenance Manual)
• 21070844: NODE1_DC_OFF: Slot Or Connector, Informational was asserted.
The compute node is turned off (DC-Off)
.