Assembly
18
SQ 05.2
SQ 14.2/SQR 05.2
4.
Place coupling [1] onto valve shaft [2] and secure against axial slipping by using
a grub screw [3] or a clamping washer and a screw with curved spring lock
washer [4]. Thereby, ensure that dimensions X, Y or L are observed (refer to
figure and table <Mounting positions for coupling>).
Figure 12: Examples: Fit coupling
[1]
Coupling
[2]
Valve shaft
[3]
Grub screw
[4]
Clamping washer and screw with curved spring lock washer
Figure 13: Mounting positions for coupling
Table 8:
Mounting position of the coupling within fitting dimensions according to AUMA definition
Dimensions [mm]
SQ 05.2
EN ISO 5211
F05
F07
X max.
3
3
Y max.
2
2
L max.
40
40
5.
Apply non-acidic grease at splines of coupling (e.g. Gleitmo by Fuchs).
SQR 14.2 Control unit - electromechanical
SQ 07.2
SQ 10.2
F05
F07
F10
F10
3
3
3
4
2
2
2
5
40
40
66
50
AC 01.2 Intrusive Profinet
SQ 12.2
SQ 14.2
F12
F12
F14
F14
4
5
5
8
5
10
10
10
82
61
101
75
F16
8
10
125