SQ 05.2
SQ 14.2/SQR 05.2
AC 01.2 Intrusive Profinet
4.
Transport and storage
4.1.
Transport
Actuator
Weights
SQR 14.2 Control unit - electromechanical
For transport to place of installation, use sturdy packaging.
Suspended load!
Death or serious injury.
Do NOT stand below suspended load.
Attach ropes or hooks for the purpose of lifting by hoist only to housing and NOT
to handwheel.
Actuators mounted on valves: Attach ropes or hooks for the purpose of lifting
by hoist to valve and NOT to actuator.
Actuators mounted to gearboxes: Attach ropes or hooks for the purpose of lifting
by hoist only to the gearbox using eyebolts and NOT to the actuator.
Actuators mounted to controls: Attach ropes or hooks for the purpose of lifting
by hoist only to the actuator and NOT to the controls.
Respect total weight of combination (actuator, actuator controls, gearbox, valve)
Secure load against falling down, sliding or tilting.
Perform lift trial at low height to eliminate any potential danger e.g. by tilting.
Figure 9: Example: Lifting the actuator
Table 5:
Weight for AC 01.2 actuator controls
with electrical connection type:
AUMA plug/socket connector with screw-type connection
Transport and storage
Weight approx. [kg]
7
13