Ngp Boards - Alcatel-Lucent OmniPCX Enterprise Manual

Hide thumbs Also See for OmniPCX Enterprise:
Table of Contents

Advertisement

INSTALLATION PROCEDURE FOR VERSION
J1.410.34.c – RELEASE 10.0
Compatibility at 100 Mbits of VH and WM1 shelves for use of CPU6 Step2 and CPU7 boards.
The CPU7 board is not allowed in a VH cabinet.
All types of shelves are or will be compatible at 100 Mbits. For VH and WM1 cabinets, compatibility
at 100 Mbits is available with the following references:
Designation
VH (10/100BaseT) Basic Rack 48V
VH (10/100BaseT) Basic Rack 48V - USA
VH (10/100BaseT) Basic Rack 90W
VH (10/100BaseT) Basic Rack 90W - USA
VH (10/100BaseT) Extension Rack 48V
VH (10/100BaseT) Extension Rack 48V - USA
VH (10/100BaseT) Extension Rack 90W
VH (10/100BaseT) Extension Rack 90W - USA
WM1 (10/100BaseT) Basic Packed 110/230V
WM1 (10/100BaseT) Basic Packed 110/230V - USA
WM1 (10/100BaseT) Basic Packed 48V
WM1 (10/100BaseT) Basic Packed 48V - USA
WM1 Batteries batch 1.2 Ah battery autonomy
WM1 Batteries batch 1.2 Ah battery autonomy - USA
Note
If the shelves referenced above are not used, the CPU6 Step2 and CPU7 boards only function at a
maximum of 10 Mbits.

7.7.8 NGP boards

This general naming concerns GD3, GA3, PowerMEX as well as INTIP3 boards.
Pay attention to always stop the software with shutdown –h now or the stop button
before unplugging a GD3/GA3/INTIP3 board. Direct unplug is forbidden.
In a Common Hardware Media Gateway, no mix between NGP boards and previous hardware
(GD, GA, MEX) is authorized. If one board has to be replaced, all the other ones will have to be
replaced.
In a Crystal Media Gateway, mix between INTIP3 and the previous INTIP/INTIP2 is authorized,
except that for main and stand-by function the same kind of boards have to be used.
All the previous compression daughter boards (MCV, MADA, GIP) are incompatible with NGP
boards as well as Armada daughter board is incompatible with GD/GA/INTIP boards.
HSL, Slanx-4 and AFU daughter boards are compatible with common hardware NGP boards.
The 10/100/1000 Base-T connector for INTIP3 is incompatible with INTIP/INTIP2 as well as the
10/100 connector for INTIP/INTIP2 is incompatible with INTIP3.
Ed. 02 / 22 June 2011
OmniPCX Enterprise
35
Reference
3BA 56191 AN
3BA 56191 UN
3BA 56193 AN
3BA 56193 UN
3BA 56192 AN
3BA 56192 UN
3BA 56194 AN
3BA 56194 UN
3BA 27112 AN
3BA 27112 UN
3BA 27113 AN
3BA 27113 UN
3BA 57106 AC
3BA 57106 UB
TC1449

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents