Emerson Bettis XTE3000 Installation, Operation And Maintenance Manual page 31

Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
MDE 255 Rev. 0
The FF2000v4 rev. 3 specific parameters are described here below:
42
43
44
45
Table 12.
Enumeration
0
1
2
3
46
Resource Block
ACTUATOR_SN
Type: STRING
Size: 28 octets
Handling: READ
It is the actuator serial number stored by the manufacturer in the nameplate data.
ACTUATOR_SIZE
Type: STRING
Size: 28 octets
Handling: READ
It is the actuator size stored by the manufacturer in the nameplate data.
WIRING_DIAGRAM
Type: STRING
Size: 28 octets
Handling: READ
It is the actuator wiring diagram stored by the manufacturer in the nameplate data.
ACTUATOR_TORQUE_EU
Type: ENUMERATED
Size: 1 octet
Handling: READ
It is the torque EU selected stored by the manufacturer in the nameplate data. It may assume
the following values:
ACTUATOR_TORQUE_THRUST
Type: STRING
Size: 7 octets
Handling: READ
It is the actuator nominal torque / thrust stored by the manufacturer in the nameplate data.
Section 7: Resource Block
Description
Torque lbf
Torque Nm
Torque lb
Torque KNF
January 2022
27

Advertisement

Table of Contents
loading

Table of Contents