Important Safety Procedures
Installation, adjustment, putting into service, use, assembly, disas-
sembly and maintenance of the Actuator is strictly reserved to quali-
fied personnel.
Before installation, operation and maintenance, read the relevant
sections of:
-
This manual
-
Quick Reference Guide: DOC.QRG.XL
Caution: Always disconnect the Air and Electrical supplies before
carrying out any form of maintenance on an Actuator.
Caution: When removing any ball valve or plug valve assemblies
from a pipe system, isolate the piping system on which the Actuator
is installed and relieve any media pressure that may be trapped in
the valve cavities before removing the Actuator for maintenance.
Caution: Always contain the Spring tension with HYTORK Retrac-
tor Rods as explained in Section 9 (Disassembly procedure). Follow
instructions for using the Retractor Rod carefully. Only HYTORK
manufactured or approved Retractor Rods are to be used for Spring
removal. As with any threaded tool that is frequently used Retractor
Rods should be checked to ensure that the threads are not worn or
damaged in any way and greased regularly. Any damaged or worn
Rods must not be used and must be destroyed.
Never attempt to 'BLOW OUT' the Pistons or the End caps from the
Actuator Body by using air pressure.
Never turn the stop screws completely out when the actuator is
under pressure
w w w . H y t o r k . c o m
XL 281
XL 2586
XL 426
XL 4581
XL 681
XL 1127
XL 1372
Numbers in brackets (#) refer to parts on the exploded view drawing
(Fig. 5).
All HYTORK XL Spares Kits are supplied with SAFEKEY assemblies
(13/14) cut to an exact length which will fit the circumference of the
End Cap (21) when fully assembled into the Actuator. Any shortened
SAFEKEY must not be used. If in doubt contact Emerson Process
Management or your local HYTORK Stocking Distributor.
Read the relevant sections carefully before continuing.
1.1
Warehouse storage
HYTORK Actuators should be stored in a clean, dry warehouse, free
from excessive vibration and rapid temperature changes.
Actuators should not be stored on any floor surface.
1.2
On site storage
HYTORK actuators should be stored in a clean, dry warehouse, free
from excessive vibration and rapid temperature changes.
Prevent moisture or dirt entering the actuator. Plug or seal both air
connection ports.
Important! Failure to follow proper storage guidelines will void war-
ranty
1.3
Lifting instructions
Use lifting equipement as required by national or local legislation.
Use lifting straps to lift the assembly of actuator and valve.
Do not attach lifting straps to only the actuator, to lift the assem-
bly of actuator and valve.
Table 2
Weight of Actuators
Double Acting
Model
Kg
XL26
1.39
XL71
2.39
XL131
3.90
XL186
4.77
XL221
6.19
XL281
7.02
XL426
7.30
XL681
8.80
XL1127
22.00
XL1372
27.00
XL2586
46.00
XL4581
83.00
Hytork XL
Spring Return with S80
Springs
Lbs
Kg
3.06
1.53
3.37
5.27
2.78
6.13
8.60
4.76
10.49
10.52
5.45
12.02
13.65
7.76
17.11
15.47
9.90
21.83
16.10
12.50
27.56
19.40
22.50
49.60
48.50
36.00
79.37
59.52
46.60
102.73
101.41
79.00
174.16
182.98
142.00
313.05
Lbs

Advertisement

loading

Summary of Contents for Emerson Hytork XL26

  • Page 1 (13/14) cut to an exact length which will fit the circumference of the End Cap (21) when fully assembled into the Actuator. Any shortened SAFEKEY must not be used. If in doubt contact Emerson Process Management or your local HYTORK Stocking Distributor.
  • Page 2 Installation Operation & Maintenance Instructions Hytork XL MAC050515 EN Rev. C May 2016 ATEX instructions for use in (potential) Operating Media, Pressures and Temperatures explosive areas Operating media 2.1 Intended use a Use clean, dry or lubricated air or inert gas. b Maximum pressure : 8 barg / 116PSI The Hytork XL series pneumatic actuators are a Group II category Note:...
  • Page 3 Rings, DURASTRIP Bearings, Washers etc. This Kit is available - For XL 26 to XL681 the Pistons (20), springs and end cap will from Emerson Process Management or its Stocking Distributors. come out - For XL 1127 to XL4581 the Retractor plate, springs and end cap will come out.
  • Page 4 Installation Operation & Maintenance Instructions Hytork XL MAC050515 EN Rev. C May 2016 Fig. 4 Hytork XL Actuator Parts Table 3 Parts and materials Pos. Description Material Note: Pos. Description Material Note: Ball Bearing Chromium Steel ‘O’ Ring (Pinion bottom) Nitrile ‘O’...
  • Page 5 Fig. 6). 16 Carefully remove Pinion Top Bearing (9) from the Body. Inspection 17 Clean and examine all parts for damage and wear. Emerson Pro- cess Management recommends ‘O’ Rings, DURASTRIP Bear- ings, SAFEKEYS, Washers, etc. are replaced using a HYTORK XL Spares Kit.
  • Page 6 Installation Operation & Maintenance Instructions Hytork XL MAC050515 EN Rev. C May 2016 10.3 Piston assembly 18 Holding the SAFEKEY close to the entry hole (cast identity letter C or D) to prevent kinking, insert the SAFEKEY into the hole and 10.3.1 Clockwise rotation gently push into place.
  • Page 7 13 Service 12.1 Spring Removal System Board. It is the policy of Emerson Process Management to give the best HYTORK’S “SPRING REMOVAL SYSTEM BOARD” contains a full possible service to our customers. We are happy to assist you in any...
  • Page 8 Process Management. This restriction also applies to the corresponding draw- ings and diagrams. Emerson Process Management has the right to change parts of the machine at any time without prior or direct notice to the client. The contents of this publica- tion are subject to change without notice.