F332
Light-Load High-Speed Operation Load Wait Time
Program Special Control Crane/Hoist Load
After the time setting of
F333
time that the Light-Load High-Speed criteria must be met until the Light-
Load High-Speed function engages.
Light-Load High-Speed Operation Load Detection Time
Program Special Control Crane/Hoist Load
This parameter determines the length of time that the load requirement must
meet the Light-Load High-Speed criteria before the Light-Load High-Speed
Enable (F330) is recognized.
Once recognized, the timer setting of
Load High-Speed function.
Light-Load High-Speed Operation Heavy-Load Detection
Time
Program Special Control Crane/Hoist Load
While operating in the Light-Load High-Speed mode, this parameter
determines the length of time that a load exceeding the Light-Load High-
Speed operation criteria may exist before the Light-Load High-Speed mode is
terminated and normal operation resumes.
Switching Load Torque During Forward Run
Program Special Control Crane/Hoist Load
While running forward, this parameter establishes the threshold torque level
that is used to determine if the Light-Load High-Speed (F331) operation may
engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated, normal operation
resumes.
Heavy-Load Torque During Forward Acceleration
Program Special Control Crane/Hoist Load
During forward acceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated, normal operation
resumes.
Heavy-Load Torque During Fixed Speed Forward Run
Program Special Control Crane/Hoist Load
While running forward at a fixed speed, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed (F331)
operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated, normal operation
resumes.
132
times out, this parameter determines the length of
F332
must expire to engage the Light-
Direct Access Number — F332
Parameter Type — Numerical
Factory Default — 1.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Direct Access Number — F333
Parameter Type — Yes
Factory Default — 1.0
Changeable During Run — Numerical
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Direct Access Number — F334
Parameter Type — Numerical
Factory Default — 5.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Direct Access Number — F335
Parameter Type — Numerical
Factory Default — 50
Changeable During Run — No
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F336
Parameter Type — Numerical
Factory Default — 150
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F337
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %