F227
RX2 Torque Reference Setpoint #2
Program Torque Setting  Setpoints RX2
This parameter is used to set the gain and bias of the RX2 input terminal when
the RX2 terminal is used as the control input while operating in the Torque
Control mode.
This is accomplished by establishing an associated V/f output pattern for a
given RX2 input level.
See RX2 Speed Reference #1 for further information on this setting.
This parameter sets RX2 Torque Reference Setpoint #2 and is the output
torque value that is associated with setting of RX2 Speed Reference #2 while
operating in the Torque control mode.
HX7+ ASD Installation and Operation Manual
Direct Access Number — F227
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Yes
Minimum — -250.00
Maximum — 250.00
Units — %