27. Press more... until SigType appears on the display.
28. Press SigType until the required signalling type is displayed.
NI-1
MFT
Mer1
Austel
ETSI
Note that you must select NI-1 for pre-NI-1 DMS switches.
29. Press A/Mu until the required encoding law setting is shown:
Mu-Law
A-Law
30. Press Dnld BC until the required bearer capability setting is shown:
Speech
Data
This menu item does not appear when using
MFT
MFT signalling.
31. Press DL Key.
This menu item only appears when using MFT
MFT
signalling. For all other signalling types, go to
step 35.
32. If you must assign a hardkey other than the Prime Directory Number
key for downloading, press the desired hardkey.
You can use hardkeys numbered 1-10 (see appendix F for hard key
locations).
33. Press more... until CACH Set appears on the display.
This menu item does not appear when using
MFT
MFT signalling.
DMS-100 and other National ISDN-1 switches.
DMS Proprietary Stimulus Signalling.
Meridian 1 .
When installing a Telecom CustomNet
telephone.
For DMS/M1 lines using ETSI protocol.
North American installations.
Australian and ETSI installations.
When speech bearer capability is used for
download calls.
When data bearer capability is used for
download calls.
M5317TX and CustomNet Installation Guide
BootROM configuration
37