Calibration failed
10.5
Normal procedures
Contingency proced-
ures
Emergency proced-
ures
Operation
The pilot can tap < Back at any time to cancel the calibration procedure.
Restart of compass calibration is possible then.
Possible reasons
GNSS is not available
•
Generic calibration error. Something went wrong.
•
Make sure to turn around slowly, around 8 s per turn
•
Make sure to have empty pockets
•
Make sure to not be close to metal objects
•
BLK2FLY positioned in wrong orientation
•
If BLK2FLY is positioned in the wrong orientation, the BLK2FLY Live
•
app waits until the BLK2FLY is in the required orientation
Flight Procedures
Procedures used during normal flight:
Take-off
•
Land
•
Change altitude
•
Operator-controlled operation procedures
•
Initiate building scan
•
Monitoring of environmental conditions
•
Monitoring of airspace
•
Always check battery level
•
BLK2FLY must always be in line of sight
•
Ensure that obstacle avoidance is always enabled
•
Contingency procedures come into effect in abnormal situations. In these situ-
ations, it is no longer possible to continue the flight using normal procedures.
The safety of the aircraft or persons on the ground is not in danger.
Especially in automatic flights, the pilot must be ready to take over the
•
control of the BLK2FLY at any time
In case of doubt for completing a mission, pause the automatic flight or
•
land the BLK2FLY. Doubts may rise due to changing environmental condi-
tions, abnormal behaviour of BLK2FLY, other aircraft close by.
Refer to
12 Troubleshooting
Safety has always highest priority.
Type
Details
Obstacle avoid-
If possible, always keep obstacle avoidance activated.
ance
This is important to ensure safety during scans and
when returning back home.
Emergency case
For example:
•
•
Turn off engines
It is possible to turn off the motors of BLK2FLY while
still flying. This way, the BLK2FLY is crash landing in its
current position. Greater damage is prevented.
•
•
for details.
BLK2FLY is flying away
Crash with another aircraft is about to happen
Refer to
Emergency off switch.
Refer to
12 Troubleshooting
for details
for details
99