Cleaning: Safety information

2.7
DANGER
High voltages.
Danger of fatal electric shock. Do not clean the char-
ging station with a high-pressure cleaner or similar
device.
Details on maintenance, cleaning and repair can be found
in the manual.
2.8
Replacing the charging cable: Safety
information
DANGER
Danger of fatal electric shock.
Switch off and secure the power supply to the
u
charging station.
NOTE
Only use genuine Webasto parts.
Installation and electrical
3
connection
DANGER
Observe the safety information provided here Safety.
To access further documents use one of the following
options:
– The Webasto Service App
Go to https://apps.apple.com/ or scan the following
QR Code to download the app from the Apple App
Store.
To download from the Google Play Store go to
https://play.google.com/ or scan the following QR
Code.
14
To use the Webasto Service App and access online
Webasto technical documentation, please scan the QR
code or the barcode on your Webasto product box.
Our operating instructions are also available on our web-
site at http://www.webasto-charging.com/
documentation. All languages can be found in the
download portal on our website.
NOTE
The Webasto Next safety concept is based on a power
supply system that is earthed at all times, which must
always be ensured by an electrician during installation.

Requirements installation space

3.1
The following points must be taken into account when
selecting the installation location for the Webasto Next:
– The lower edge of the enclosed mounting template
must be at a minimum distance of 90 cm above the
ground during installation. See Fig: Live Wall mount-
ing.
– If several charging stations are installed next to each
other, a spacing of at least 200 mm must be main-
tained between each station.
– The mounting surface must be solid and strong.
– The mounting surface must be completely flat (max. 1
mm difference between the individual mounting
points).
– The mounting surface must not contain any flammable
substances.
– A cable run from the charging station to the vehicle as
short as possible.
– No risk of driving over the charging cable.
– Possible electrical connections from infrastructure.
– Pavements and escape routes must not be obstructed.
– We recommend an installation location that is protec-
ted against direct sunlight for optimum and fault-free
operation.
– The usual parked position of the vehicle, taking ac-
count of the position of the charging plug on the
vehicle.
– Consideration of local building and fire protection reg-
ulations.
NOTE
The mounting distance between the bottom edge of
the charging station and the floor must be at least 0.9
m.
3.2

Criteria for the electrical connection

The maximum charging current is factory set and is indic-
ated on the type label of the charging station. The max-
imum charging current can be reduced to the value of
the installed circuit breaker using DIP switches.
NOTE
The current value of the selected protective device
must not fall below the current value specified on the
type label for the charging station or the value set us-
ing the DIP switch.
See chapter 3.7, "DIP switch settings" on page 16.
The installation requirements for the charging station
should be checked by a qualified electrician before start-
ing connection works.
Comply with the nationally applicable regulations of the
authorities and power supply companies, e.g. registration
of installation of a charging station.
NOTE
In some countries, single-phase charging is limited to
a defined current. Please observe the local connection
requirements.
All protective devices specified below must be designed
such that every power supply pole of the charging station
is disconnected in the case of a fault. You must meet na-
tional installation regulations and standards when select-
ing the protective device.
Dimensioning of the Residual Current
3.2.1
Circuit Breaker (RCCB)
The national installation regulations generally apply. Un-
less otherwise specified therein, each charging station
must be protected by an appropriate residual current
device (RCD type A) with a trip current of ≤ 30 mA.