Specifications And Reference; Typical Power Consumption - ETC ColorSource PAR v1.7 Installation Manual

Hide thumbs Also See for ColorSource PAR v1.7:
Table of Contents

Advertisement

ETC Installation Guide
ColorSource PAR v1.7/v3.0

Specifications and Reference

For current and complete compliance and specifications, see the ColorSource
PAR datasheet at etcconnect.com.
Environment
The ColorSource PAR operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan. The ColorSource PAR is for indoor use only.
Maximum recommended ambient operating temperature: Ta = 40°C 
(104°F)
Maximum anticipated external surface temperature at 40°C ambient:
Tmax = 80°C (176°F)
External temperatures after 5 minutes of full-brightness operation at
25°C (77°F) ambient: 30°C (86°F)
External Temperature (steady state achieved) at 25°C (77°F): 41°C (106°F)
Electrical
Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.
Maximum power consumption is 120 W.
Up to 9 luminaires (15 A max) may be linked via power thru connector
(10 luminaires total per circuit) when used with an R20 Relay Module or
Unison Echo Relay Panel. Consult breaker trip curves when used with
other equipment. Requires power from a non-dimmable source.
Inrush:
120 V: 35 A (first half-cycle)
-
240 V: 49 A (first half-cycle)
-

Typical Power Consumption

Idle
Direct at Full
ColorSource PAR
100 V
Power
Current
1.22 W
0.03 A
107 W
1.07 A
120 V
Power
Current
1.21 W
0.03 A
106 W
0.88 A
Page 13 of 16
230 V
Power
Current
1.14 W
0.03 A
104 W
0.46 A