ETC Desire Series Installation Manual
Hide thumbs Also See for Desire Series:

Advertisement

Quick Links

E T C I n s t a l l a t i o n G u i d e
®
Desire
Series D22
Introduction
ETC's Desire D22 is designed for indoor installations and has a rugged die-cast
enclosure, steel mounting yoke, and noise-free, fan-less operation.
The D22 can be pipe mounted with a C-clamp, canopy mounted, or track mounted.
Mounting accessories are available. Contact ETC Customer Service for
assistance; contact information is located at the bottom of this page.
For information about the operation of the D22 Desire Series, refer to Desire
Series by ETC D22, D40, D40XT, D60 User Manual. ETC manuals are available
for download at http://www.etcconnect.com/downloads.aspx.
C A U T I O N :
W A R N I N G :

Specifications

Environment
Operates in ambient temperatures of 0°C to +40°C (32°F to 104°F).
C A U T I O N :
Corporate Headquarters
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Rome, IT
Via Pieve Torina, 48, 00156 Rome, Italy
Holzkirchen, DE
Ohmstrasse 3, 83607 Holzkirchen, Germany
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Service: (Americas)
service@etcconnect.com
Web:
www.etcconnect.com
Copyright © 2013 ETC. All Rights Reserved.  Product information and specifications subject to change.
7411M2100  Rev C  Released 2013-11  ETC intends this document to be provided in its entirety.
De sir e D2 2
Portable
Do not attempt to install or use a fixture until you read and
understand the installation instructions and safety labels.
This fixture must be installed by a qualified electrician in
accordance with all national and local electrical and
construction codes and regulations.
Risk of eye injury. Do not stare directly into the light.
Do not operate in proximity to flammable materials.
Tel +39 (06) 32 111 683
Tel +49 (80 24) 47 00-0
(UK)
service@etceurope.com
Pa ge 1 of 8
Canopy Mount
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8752 8486
Fax +49 (80 24) 47 00-3 00
(DE)
techserv-hoki@etcconnect.com
Ele ct r on ic T he at r e Con tr o ls, I nc.
Track Mount
Tel +608 831 4116
Fax +608 836 1736
Fax +44 (0)20 8896 2000
Tel +852 2799 1220
(Asia)
service@etcasia.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Desire Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ETC Desire Series

  • Page 1: Specifications

    Copyright © 2013 ETC. All Rights Reserved.  Product information and specifications subject to change.  7411M2100  Rev C  Released 2013-11  ETC intends this document to be provided in its entirety. De sir e D2 2 Pa ge 1 of 8...
  • Page 2 • Connection of DMX/RDM thru to the next DMX device. This connection may also be either Belden 9729 or Cat5. The connector is not provided. Order the appropriate DMX termination kit for the cable type used from ETC (Belden 9729 use 4100A1012 or Cat5 use 4100A1013). Termination instructions and the appropriate connector is provided with the termination kit.
  • Page 3 The Desire D22 Portable is provided with a permanently installed power cord with 3-prong Edison connector. Region specific connectors are available. Contact ETC for available options. The Canopy fixture is provided with power and data wired to the canopy and should be terminated in a voltage-separated junction box (provided by others).
  • Page 4: Installation

    Installation Termination The D22 Desire Series requires termination at the last fixture on a DMX/RDM line with a 120 ohm resistor. • The Portable fixture is self terminated. • The Track fixture is terminated with a DataTrack DMX Term Block, ETC Part # 7066A1030.
  • Page 5: Installing The Canopy Fixture

    Installing the Canopy Fixture The Canopy D22 Desire Series is installed on to a RACO 232 series 4 x 2-1/8 inch deep double junction box. The fixture is supplied with a divider to separate the data network from the line voltage inside the junction box.
  • Page 6: Canopy Mounting Plate Installation

    Plug in the input DMX/RDM connector (and thru DMX/RDM connector if used) to the appropriate location on the terminal board. Step 7: Attach the mounting plate to the junction box, ensuring the cables are properly routed inside the box. Desire Series D22...
  • Page 7: Canopy Fixture Installation

    Canopy Fixture Installation Step 1: Strip the fixture’s power wires back 1/2 inch (13mm). Step 2: Using the hole in the mounting bracket, hang the canopy on the Installation hook. Installation Step 3: Following the label on the mounting plate, hook and attach the power wires to the power block.
  • Page 8: Installing The Tr Ack Fixture

    W A R N I N G : When using the circuit selection lock, ensure the selected circuit is a constant power circuit. Dialing into a dimmable circuit may cause fixture damage that will void the ETC warranty. Step 4: Focus the fixture.

This manual is also suitable for:

Desire d22

Table of Contents