6. You can change the Len and Pos values by pressing the [PREV] or
[NEXT] keys to move the cursor to the field to change, and then entering
a new value.
7. Press the [
] key to enter new length or position values to the
displayed control address.
8. Press [NEXT] again to display the status bits.
The status bits for a PLC are displayed on two screens:
File=R006
Elem= 010
Press [NEXT] again to display the remaining PLC status bits:
File=R006
Elem= 010
The status bits for an SLC are shown on one screen:
File=R006
Elem= 010
9. To exit, press the [MODE] key to return to the initial P-A/D screen.
You can press the [MODE] key at any time during the P-A/D function.
10. Pressing the [MENU] key at the P-A/D screen exits the P-A/D function
and displays the Main Menu.
Appendix C
DTAM Micro
Special Controller Functions
En Eu Dn Em
Bits:
0
0
0
0
(Enable,
Enable Unload,
Done,
Empty)
Status
Er Ul In Fd
Bits:
0
0
0
0
(Error,
Unload,
Inhibit,
Found)
Status
En Dn Er Ul In
Bits:
0
0
0
0 0
(Enable,
Done,
Error,
Unload,
Status
Inhibit)
C–11