DRIP PIPING LINEUP ARRANGEMENTS

The following illustrations below show typical
arrangements for installing drip pipes for a
lineup of merchandisers. Illustrations are for
reference only. Piping may vary with location
and access to hub drain(s). Each merchandiser
waste outlet must be individually piped to a
1
hub drain if
/
in. drip piping pitch cannot be
4
maintained.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
NOTE: No more than two merchandisers
are to be piped per water seal. Do not install
water seal between two merchandiser waste
outlets that are piped together. (Double water
seals in series will cause an air lock and prevent
drainage.)