6-6
eRVIce
Hand Rail Heater Connections are Located in Left
Front Corner of Merchandiser (Near Serial Plate)
7. Disconnect and remove hand rail heater
from wireway.
8. Replace heater connections and re-route
new heater through internal front joint trim
and onto hand rail retainers as shown.
G rounding Wire
Harnes s
C orner Cap
B racket
Metal top rail must be properly grounded.
R emove Screw
R emove
C orner Cap
P/N 0467434_P
G rounding Wire
FWEG Heater Connections are at Right Rear Corner
9. Clean rail surfaces thoroughly, then install
10. Reinstall parts in reverse order. Any
S crew
To avoid serious injury or death from electrical
shock, always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.